Calibrate the OTS tool setting probe (P/N 34080-2): stylus level, then the OTS location, tool length and tool diameter. To calibrate the OMP40-2 spindle probe (P/N 34080-1), see VMCsi Probe Part Option - Calibrate Spindle Probe.

Two paths, depending on your calibration tool:

Calibration pin: Steps 6 to 10, then Step 13 onward.

Precision calibration tool: Steps 11 and 12, then Step 13 onward.

    • The OTS must already be mounted and configured. VMCsi Probe Tool Option - Set Up Tool Setting Probe

    • You need a 0.0001 in dial indicator, metric Allen wrenches, a tool setter dial, a 1-2-3 block, and a calibration tool (pin or precision tool).

    • Recalibrate after the stylus or break stem is replaced, or after a crash.

  1. The top of the stylus must be level side to side (Y) and front to back (X). Mount a 0.0001 in dial indicator in the spindle, facing forward, tip pointing down. Jog until the indicator touches the top of the stylus. Zero it at the edge.
    • The top of the stylus must be level side to side (Y) and front to back (X).

    • Mount a 0.0001 in dial indicator in the spindle, facing forward, tip pointing down.

    • Jog until the indicator touches the top of the stylus. Zero it at the edge.

    • Sweep along Y. Level must be within ±0.0001 in.

    • Adjust the two side set screws to level the stylus:

    • The right screw tilts the stylus right; the left screw tilts it left.

    • Adjust until level is within tolerance.

    • Torque both screws to 0.52 to 0.66 lbf-ft.

  2. Sweep the indicator along X (front to back).
    • Sweep the indicator along X (front to back).

    • Level must be within ±0.0001 in.

    • Adjust with a 4 mm Allen wrench.

    • To raise the front: loosen screw #2, adjust screw #1.

    • To lower the front: loosen screw #1, adjust screw #2.

    • Recheck level and repeat as needed.

    • When within tolerance, tighten both screws. Torque to 3.40 to 4.13 lbf-ft.

  3. Required only if the calibration tool is not already in the tool list. It is usually added at the factory. Press [JOG] on the MCP. Go to [Machine] → [Act. values Machine]. Axis values now show with an "M" prefix.
    • Required only if the calibration tool is not already in the tool list. It is usually added at the factory.

    • Press [JOG] on the MCP.

    • Go to [Machine] → [Act. values Machine]. Axis values now show with an "M" prefix.

    • Go to [Tool List]. Choose a location outside the ATC range: not 1 to 24 on a 24-tool ATC, not 1 to 40 on a 40-tool ATC.

    • Press [New tool].

    • Select [Spec. tool 700-900], then [725 - Calibrating tool].

    • Press [OK].

  4. Choose the path for the calibration tool your shop uses. Both paths end at Step 13.
    • Choose the path for the calibration tool your shop uses. Both paths end at Step 13.

    • Calibration pin:

    • Do Steps 6 to 10, then Step 13.

    • Precision calibration tool:

    • Do Steps 11 and 12, then Step 13.

  5. Enter the calibration pin length (flange to tip) plus 0.25 in. Enter the pin diameter (for example 0.5, as shown).
    • Enter the calibration pin length (flange to tip) plus 0.25 in.

    • Enter the pin diameter (for example 0.5, as shown).

    • Press [Machine], then [Meas. tool].

    • Press [Calibrate fixed pt.].

    • The Z reference (fixed point) is set at the factory. Step 7 is required only if the Z reference has changed. Otherwise skip to Step 8.

  6. Required only if the Z reference has changed. Place a tool setter dial (2 in) on a 1-2-3 block on the table, as shown.
    • Required only if the Z reference has changed.

    • Place a tool setter dial (2 in) on a 1-2-3 block on the table, as shown.

    • Jog Z down slowly until the spindle base (not the drive keys) contacts the dial.

    • Keep jogging down until the dial reads zero.

    • In the "Calibrate: fixed point" window, enter 4.000 in in the DZ field.

    • Press [Calibrate], then [Back].

  7. Press [T, S, M], then tap the T field. Press [Select tool]. In the "Tool selection" window, select the calibration tool and press [OK].
    • Press [T, S, M], then tap the T field.

    • Press [Select tool].

    • In the "Tool selection" window, select the calibration tool and press [OK].

    • The control prompts you to load the tool by hand.

  8. Press [CYCLE START]. Press [DOOR OPEN] to unlock the doors. Load the calibration pin into the spindle by hand, then close the doors.
    • Press [CYCLE START].

    • Press [DOOR OPEN] to unlock the doors.

    • Load the calibration pin into the spindle by hand, then close the doors.

    • Press [CYCLE START] again to finish the tool change.

    • The T field now shows the calibration tool.

  9. Press [Meas. tool], then [Length manually]. Place the tool setter dial on a 1-2-3 block on the table (4 in total). Jog Z down until the dial reads zero.
    • Press [Meas. tool], then [Length manually].

    • Place the tool setter dial on a 1-2-3 block on the table (4 in total).

    • Jog Z down until the dial reads zero.

    • In the "Measure: length manually" window:

    • Set Ref. point to [Fixed pt.].

    • Enter 4.000 in in the DZ field.

    • Press [Set length].

    • The L value in the tool data updates. Skip to Step 13.

  10. Enter the length and diameter engraved on the precision calibration tool (see image). Press [JOG], then [T, S, M]. Press [Select tool], select the calibration tool, and press [OK].
    • Enter the length and diameter engraved on the precision calibration tool (see image).

    • Press [JOG], then [T, S, M].

    • Press [Select tool], select the calibration tool, and press [OK].

  11. Press [CYCLE START]. Press [DOOR OPEN] to unlock the door.
    • Press [CYCLE START].

    • Press [DOOR OPEN] to unlock the door.

    • Load the calibration tool into the spindle by hand and close the door.

    • Press [CYCLE START] again to finish the tool change.

  12. Jog the calibration tool to about 0.5 in above the stylus, centered in X and Y. Press [Meas. tool], then [Calibrate probe]. In the "Calibrate: probe" window, press [CYCLE START].
    • Jog the calibration tool to about 0.5 in above the stylus, centered in X and Y.

    • Press [Meas. tool], then [Calibrate probe].

    • In the "Calibrate: probe" window, press [CYCLE START].

    • The tool touches the top and sides of the stylus.

    • When it finishes, the window shows the machine values and trigger points.

    • Run the calibration three times and note the machine values and trigger points each run.

    • Confirm they repeat. If they do not, recheck stylus level (Steps 2 and 3) and repeat.

  13. Press [Back], then [Length auto]. Press [CYCLE START].
    • Press [Back], then [Length auto].

    • Press [CYCLE START].

    • The machine positions the calibration tool over the stylus and measures its length.

    • The measured length should match the value you entered. If it does not, rerun Step 13.

  14. Press [Back], then [Diameter auto]. Press [CYCLE START].
    • Press [Back], then [Diameter auto].

    • Press [CYCLE START].

    • The machine measures the tool diameter and logs it.

    • The measured diameter should match the tool table value. If it does not, rerun Step 13.