This procedure re-establishes the absolute encoder reference, and therefore machine zero, on a TC820LTY-Ssi. It covers five servo axes: Q, X, Y, Z1 and Z2.

  1. This procedure overwrites machine zero on X, Y, Z1 and Z2. The archive is the only way back to the machine's current state.
    • This procedure overwrites machine zero on X, Y, Z1 and Z2. The archive is the only way back to the machine's current state.

    • Create a complete machine archive before touching anything.

    • Archive Current System

  2. The Z1 and Z2 references use gage blocks.
  3. Press [JOG] and [REF POINT] on the MCP.
    • Press [JOG] and [REF POINT] on the MCP.

    • On the [Machine] screen, look for the reference icon beside each axis name: MQ1, MX1, MY1, MZ1 and MZ2.

    • The black and white circle means the axis has a reference. No icon means it does not.

    • All servo axes must show the icon before the machine is operational.

    • MC1 and MC3 are the main and sub spindles. They reference themselves the first time they rotate.

    • MC2 is the driven tool spindle. It references itself the first time it rotates.

    • The icon means only that MD34210 = 2, that the control has marked the reference valid. It does not prove the reference is correct.

  4. MD34090 $MA_REFP_MOVE_DIST_CORR. The calibration itself, the offset between machine zero and the encoder zero. The control writes it, not you.
    • MD34090 $MA_REFP_MOVE_DIST_CORR. The calibration itself, the offset between machine zero and the encoder zero. The control writes it, not you.

    • MD34100 $MA_REFP_SET_POS. The coordinate you tell the control the axis is standing at. This is your input.

    • MD34210 $MA_ENC_REFP_STATE. Records whether this axis is referenced. Siemens calls it the adjustment status of the absolute encoder. It holds one of these values:

    • 0. Not calibrated. The encoder has no reference to the physical position.

    • 1. Calibration enabled. The control will accept MD34100. This is the state you set.

    • 2. Calibrated. Written by the control, not by you.

    • With MD34210 = 1, the control transfers MD34100 as the absolute value and computes MD34090 from it. That is the whole mechanism this guide runs on.

    • Because MD34090 is computed from MD34100, a wrong MD34100 produces a wrong machine zero with no alarm and no icon difference.

    • You only need this step on an axis that is already referenced and has to be re-referenced. If the axis shows no reference icon, skip this step and carry on with that axis.

    • Move the axis to its reference position before you clear the reference.

    • This puts the axis about where it needs to be so the soft limits do not get in the way once the old reference is cleared.

    • Go to [Setup] → [Mach. Data] → [Axis MD] → [Select Axis] and select the axis you are working on. Confirm the top right banner names it before you enter anything.

    • Press [Search], enter 34210, press [OK], and set MD34210[0] = 0.

    • Power cycle the machine.

    • The old reference is now gone. That axis will now accept a new one.

  5. The Q axis is the rotational position of the turret.
    • The Q axis is the rotational position of the turret.

    • Go to [Machine] → [TSM] → [Select Tool]. Select Tool 1 and press [Cycle Start].

    • Confirm the turret has fully indexed and locked.

  6. Before you start, MD34210[0] must read 0 on MQ1. 0 means the axis has no reference and will accept a new one. If it reads 2, it still holds its old reference and will not take a new one. Go back to Step 6, remove it, and return here.
    • Before you start, MD34210[0] must read 0 on MQ1. 0 means the axis has no reference and will accept a new one. If it reads 2, it still holds its old reference and will not take a new one. Go back to Step 6, remove it, and return here.

    • Go to [Setup] → [Mach. Data] → [Axis MD] → [Select Axis] → [MQ1/SERVO] → [OK].

    • Confirm the top right banner reads MQ1 before entering anything.

    • Press [Search], enter 34210, press [OK].

    • Set MD34210[0] = 1.

  7. Go to [Diagnostics] → [NC/PLC Variable]. In an empty Variable row, enter DB37.DBX4.7
    • Go to [Diagnostics] → [NC/PLC Variable].

    • In an empty Variable row, enter DB37.DBX4.7

    • Set the Format to [B].

    • On the MCP, press [JOG] and [REF POINT].

    • Press [Change], enter 1 under Value, press [Input] → [OK]. The bit returns to 0 on its own.

    • Confirm the Q axis now shows the reference icon.

  8. Mount TRAK Part 35723, HOLDER-BORING BAR-1.5"-BMT65, in turret Position 1.
    • Mount TRAK Part 35723, HOLDER-BORING BAR-1.5"-BMT65, in turret Position 1.

    • Any BMT65 boring bar holder with a 100 mm center height also works.

    • The center height is in the holder designation. 35723 reads B65 BTH 18-38.1 CH100 L120. CH100 is the center height in millimeters.

    • Do not substitute a holder with a different center height. MD34100[0] for X is 100 mm because the holder is. If you do not have a 100 mm holder, stop and call TRAK Service.

    • X and Y are referenced from one alignment. Do this once and it serves both axes.

    • Insert the centering indicator into the chuck.

    • Go to [Machine] and press [Act. values MCS] to display machine coordinates.

    • Bring the centering indicator into contact with the bore of the toolholder.

    • Jog X and Y until the tool center and the spindle center are coincident.

    • Sweep to confirm. Deviation should be under 0.001 in.

    • Do not move X or Y again until both references are set.

  9. Go to [Setup] → [Mach. Data] → [Axis MD] → [Select Axis] → [MX1/SERVO] → [OK].
    • Go to [Setup] → [Mach. Data] → [Axis MD] → [Select Axis] → [MX1/SERVO] → [OK].

    • Confirm the top right banner reads MX1. Press [Search], enter 34100, press [OK].

    • On MX1, confirm MD34100[0] = 3.937008, which is exactly 100.000 mm, the center height of holder 35723.

    • Select [MY1/SERVO] and confirm the banner reads MY1. Press [Search], enter 34100, press [OK].

    • On MY1, confirm MD34100[0] = 0.

    • With the bore on the spindle centerline, X is 100 mm (3.937008 in) and Y is 0. X is 100 mm because X zero is the turret face on center and the holder puts the bore 100 mm out from that face. Y is 0 because Y zero is the centerline itself.

    • If either value does not match, correct it before referencing. Whatever sits in MD34100[0] becomes the machine coordinate when you set the reference.

  10. Before you start, MD34210[0] must read 0 on both MX1 and MY1. 0 means the axis has no reference and will accept a new one. If either axis reads 2, it still holds its old reference and will not take a new one. Go back to Step 6, remove it, and return here.
    • Before you start, MD34210[0] must read 0 on both MX1 and MY1. 0 means the axis has no reference and will accept a new one. If either axis reads 2, it still holds its old reference and will not take a new one. Go back to Step 6, remove it, and return here.

    • Go to [Setup] → [Mach. Data] → [Axis MD] → [Select Axis] → [MX1/SERVO] → [OK].

    • Confirm the banner reads MX1. Press [Search], enter 34210, press [OK]. Set MD34210[0] = 1.

    • Select [MY1/SERVO]. Confirm the banner reads MY1. Press [Search], enter 34210, press [OK]. Set MD34210[0] = 1.

    • On the MCP, turn on [JOG] and [REF. POINT].

    • Press the [X] axis button, then press [+].

    • Press the [Y] axis button, then press [+].

    • Confirm MD34210[0] now reads 2 on both MX1 and MY1.

  11. Confirm X and Y both show the reference icon. Go to [Machine] and press [Act. values MCS].
    • Confirm X and Y both show the reference icon.

    • Go to [Machine] and press [Act. values MCS].

    • With the tool center still on the spindle center, confirm X reads 3.9370 and Y reads 0.0000.

    • If either reading is wrong, the reference is wrong. Do not continue. Re-check MD34100[0].

    • Measure the turret, front face to back face. This is W.

    • Measure square to both faces, at or beside turret Position 1.

    • Measure this turret. Do not use W from another machine or a drawing. Every turret gets its own measurement.

    • Write W down.

    • W goes straight into machine zero. Nothing downstream catches an error in it after this step.

  12. Place the 6.000 in gage block against the main spindle face.
    • Place the 6.000 in gage block against the main spindle face.

    • Jog the turret forward until the turret front face makes light contact with the block.

    • No visible gap, but do not compress or deflect the block.

    • Leave the axis where it is. Do not move Z until the reference is set.

    • The turret front face is now 6.000 in from the main spindle face.

    • Calculate 6.000 + W/2. The 6.000 is the block. The W/2 carries the datum from the turret front face back to the turret centerline.

    • Go to [Setup] → [Mach. Data] → [Axis MD] → [Select Axis] → [MZ1/SERVO] → [OK].

    • Confirm the top right banner reads MZ1.

    • Press [Search], enter 34100, press [OK].

    • Enter the calculated value in MD34100[0].

  13. Before you start, MD34210[0] must read 0 on MZ1. 0 means the axis has no reference and will accept a new one. If it reads 2, it still holds its old reference and will not take a new one. Go back to Step 6, remove it, and return here.
    • Before you start, MD34210[0] must read 0 on MZ1. 0 means the axis has no reference and will accept a new one. If it reads 2, it still holds its old reference and will not take a new one. Go back to Step 6, remove it, and return here.

    • Still on [MZ1/SERVO], press [Search], enter 34210, press [OK].

    • Set MD34210[0] = 1.

    • On the MCP, turn on [JOG] and [REF. POINT].

    • Press the [Z] axis button, then press [+].

    • MD34210[0] flips to 2 on its own.

  14. Confirm MZ1 now shows the reference icon.
    • Confirm MZ1 now shows the reference icon.

    • Go to [Machine] and press [Act. values MCS].

    • With the turret front face still in contact with the block, confirm MZ1 reads the value you calculated and entered.

    • If it does not, the reference is wrong. Do not continue. Re-check the value you entered in MD34100[0].

  15. Retract the turret fully clear of the working area.
    • Retract the turret fully clear of the working area.

    • Place the 12.000 in gage block between the main spindle and sub spindle faces.

    • Jog the sub spindle forward until it makes light contact with the block.

    • No visible gap, but do not compress or deflect the block.

    • Leave the axis where it is. Do not move Z2 until the reference is set.

    • The sub spindle face is now 12.000 in from the main spindle face. There is no W/2 on this axis: the sub spindle face is the datum itself.

  16. Go to [Setup] → [Mach. Data] → [Axis MD] → [Select Axis] → [MZ2/SERVO] → [OK].
    • Go to [Setup] → [Mach. Data] → [Axis MD] → [Select Axis] → [MZ2/SERVO] → [OK].

    • Confirm the top right banner reads MZ2.

    • Press [Search], enter 34100, press [OK].

    • Enter 12.000 in MD34100[0].

  17. Before you start, MD34210[0] must read 0 on MZ2. 0 means the axis has no reference and will accept a new one. If it reads 2, it still holds its old reference and will not take a new one. Go back to Step 6, remove it, and return here.
    • Before you start, MD34210[0] must read 0 on MZ2. 0 means the axis has no reference and will accept a new one. If it reads 2, it still holds its old reference and will not take a new one. Go back to Step 6, remove it, and return here.

    • Still on [MZ2/SERVO], press [Search], enter 34210, press [OK].

    • Set MD34210[0] = 1.

    • On the MCP, turn on [JOG] and [REF. POINT].

    • Press the [Z2] axis button, then press [+].

    • MD34210[0] flips to 2 on its own.

  18. Confirm MZ2 now shows the reference icon. Go to [Machine] and press [Act. values MCS].
    • Confirm MZ2 now shows the reference icon.

    • Go to [Machine] and press [Act. values MCS].

    • With the sub spindle still in contact with the block, confirm MZ2 reads 12.000.

    • If it does not, the reference is wrong. Do not continue. Re-check MD34100[0].

    • If machine zero has moved, anything calibrated against machine position is now wrong.

    • Recalibrate the tool setter. Probe calibration is machine position based.

    • Calibrate Tool Setters

  19. Create a complete machine archive now that the references are set.