Skip to main content

Introduction

These procedures cover the basic hardware kit installation on Step 1. Additional steps help the Factory or FST with the complete 4th Axis installation on a TMC. Here are the steps along with the Dozuki Guide References:

Please make sure to load software version 2.3.0 or higher prior to 4th axis installation.

1. Install on TMC - TMC 4 Axis 31538: Install Hardware "Ready Kit" & Test -- Steps 1 - 7 are the hardware "Ready Kit", Steps 8 onward start testing the hardware install when the 4th Axis unit is available.

2. Y, Z Offset, Base Tool - TMC 4 Axis 31538: FST Install & Test

3. Backlash - TMC 4 Axis 31538: Set Backlash

Reference Document:

A pdf version of drawing 31538 is attached to the end of this document. It covers the location of all items, how the parts are assembled, and the part numbers used to build the drive.

  1. Service Code 128 allows you to enter a backlash compensation for each axis. The A axis backlash is to be entered in a decimal angle.
    • Service Code 128 allows you to enter a backlash compensation for each axis. The A axis backlash is to be entered in a decimal angle.

  2. Mount an indicator on the 4th axis unit as shown on the left image.
    • Mount an indicator on the 4th axis unit as shown on the left image.

    • Go to DRO mode and load your indicator a few thousandths or 50 microns from one direction and set zero on your indicator and on your DRO.

    • It is best to use the .0001” or 0.002 mm button when using the EHW for this.

    • Rotate the 4th axis in the same direction until you see a few thousandths or 50 microns of movement on the indicator.

    • Reverse the axis and go back to zero on the indicator.

    • The amount of error you see on your DRO screen is your backlash.

    • Enter this into service code 128.

    • Now redo this procedure and make sure the DRO and indicator both come back to zero.

    • Adjust as necessary.

Finish Line

One other person completed this guide.

Attached Documents

Trent Plungas

Member since: 01/14/2021

64 Guides authored

Team

Siemens Internal Member of Siemens Internal

48 Members

23 Guides authored

0 Comments

Add Comment

View Statistics:

Past 24 Hours: 0

Past 7 Days: 0

Past 30 Days: 0

All Time: 90