Tools
Parts
-
-
Turn off power to the machine.
-
Unplug all the connectors on the pendant arm/pendant platform side of the pendant.
-
Remove the pendant from the pendant arm by removing the (4) M6-1.0x25 25B screws that secure it in place.
-
All RX Pendants (mill/lathe) utilize the same mounting screws.
-
Mount the replacement pendant on the arm/platform with the (4) mounting screws.
-
Reconnect all the previously removed cable connections.
-
Either reload old configuration file using service code 141 or recalibrate and enter new backlash calibration constants.
-