Skip to main content
  1. Shut power off to machine. The servos are run by 200 to 240 VAC.   There is possibility of death by electrocution! Remove servo data cable & axis encoder cable from servo drive.
    • Shut power off to machine. The servos are run by 200 to 240 VAC. There is possibility of death by electrocution!

    • Remove servo data cable & axis encoder cable from servo drive.

    • Remove control circuit power input wires (L1-6 7 L2-6).

    • Remove motor power input wires (L1-7, L2-7 & L3-7).

    • Remove motor power output wires (U, V & W).

    • Remove (2) ground wires.

    • Remove (2) SHCS's and remove servo drive.

    • Reverse steps for re-installation.