Parts
- 29980-8TUR
- 29980-1630US-X
- 29980-1630US-Z
- 29980-1845-X
- 29980-1845-Z
- 29980-2470-X
- 29980-2470-Z
- 29980-30120-X
- 29980-30120-Z
- 29980-DPMRX2-X
- 29980-DPMRX2-Y
- 29980-DPMRX2-Z
- 29980-DPMRX3-X
- 29980-DPMRX3-Y
- 29980-DPMRX3-Z
- 29980-DPMRX5-X
- 29980-DPMRX5-Y
- 29980-DPMRX5-Z
- 29980-DPMRX7-X
- 29980-DPMRX7-Y
- 29980-DPMRX7-Z
-
-
Shut power off to machine. The servos are run by 200 to 240 VAC. There is possibility of death by electrocution!
-
Remove servo data cable & axis encoder cable from servo drive.
-
Remove control circuit power input wires (L1-6 7 L2-6).
-
Remove motor power input wires (L1-7, L2-7 & L3-7).
-
Remove motor power output wires (U, V & W).
-
Remove (2) ground wires.
-
Remove (2) SHCS's and remove servo drive.
-
Reverse steps for re-installation.
-
Almost done!
Finish Line