Skip to main content

You're viewing a previously published revision of this guide.  View latest revision

Older Newer
  1. Review the jogstick drawing and note color coded items for future steps Note the orientation of the jogstick relative to direction of travel Note the pinout of the jogstick connector relative to the direction of the jogstick handle
    • Review the jogstick drawing and note color coded items for future steps

    • Note the orientation of the jogstick relative to direction of travel

    • Note the pinout of the jogstick connector relative to the direction of the jogstick handle

    • Note jogstick connector pinout. Test leads are inserted in "B" and "E" of the jogstick connector

  2. Set meter in continuity mode as shown Note that the meter reads OL which means no continuity
    • Set meter in continuity mode as shown

    • Note that the meter reads OL which means no continuity

    • Move jogstick handle in the X- direction

    • Voltmeter now reads .000 which means that there is continuity as expected

Mark Takahashi

Member since: 01/21/2020

2 Guides authored

Team

Siemens Internal Member of Siemens Internal

51 Members

35 Guides authored

View Statistics:

Past 24 Hours: 0

Past 7 Days: 4

Past 30 Days: 6

All Time: 132